免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠胃泌素抑制肽(GIP)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1581
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat GIP(Gastric Inhibitory Polypeptide) ELISA Kit
Reactivity: Rat
Alternative Names: Incretin hormone;? Glucose Dependent Insulinotropic Peptide
Assay Type: Competitive Inhibition
Sensitivity: 27.1 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: Serum, plasma and other biological fluids
Assay Length: 2h
Research Area: Endocrinology;Gastroenterology;Hormone metabolism;
Uniprot ID: Q06145
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat GIP protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat GIP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat GIP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 0.185
2500.00 0.389
1250.00 0.621
625.00 0.833
312.50 1.119
156.25 1.565
78.13 1.813
0.00 2.101

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GIP and the recovery rates were calculated by comparing the measured value to the expected amount of GIP in samples.
Matrix Recovery range Average
serum(n=5) 88-99% 93%
EDTA plasma(n=5) 86-98% 92%
Heparin plasma(n=5) 82-98% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GIP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-104% 97-106% 82-91% 85-96%
EDTA plasma(n=5) 85-93% 87-96% 97-105% 95-102%
Heparin plasma(n=5) 78-92% 79-93% 94-106% 83-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
内乡县| 江陵县| 米脂县| 密云县| 永靖县| 潮州市| 肥西县| 景泰县| 西青区| 祁连县| 太原市| 旌德县| 克拉玛依市| 汉源县| 奉贤区| 海宁市| 平谷区| 阿拉善左旗| 遵义县| 潮州市| 九江县| 深泽县| 龙海市| 沐川县| 神池县| 白城市| 体育| 闽侯县| 法库县| 长葛市| 定襄县| 扬州市| 双柏县| 合肥市| 建宁县| 广丰县| 揭西县| 青岛市| 库尔勒市| 定边县| 绥江县|