免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人B-淋巴細胞激活抗原B7-2(LAB7-2)酶聯(lián)免疫吸附檢測試劑盒
ELK1606
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human LAB7-2(B-Lymphocyte Activation Antigen B7-2) ELISA Kit
Reactivity: Human
Alternative Names: CD86; B7-2; B70; FUN-1; CD28LG2; CD28 Antigen Ligand 2,B7-2 Antigen; CTLA-4 counter-receptor B7.2
Assay Type: Sandwich
Sensitivity: 0.274 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;CD & Adhesion molecule;Tumor immunity;Infection immunity;Immune molecule;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human LAB7-2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human LAB7-2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human LAB7-2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human LAB7-2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.131 2.036
5.00 1.563 1.468
2.50 1.251 1.156
1.25 0.896 0.801
0.63 0.453 0.358
0.32 0.335 0.240
0.16 0.230 0.135
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant LAB7-2 and the recovery rates were calculated by comparing the measured value to the expected amount of LAB7-2 in samples.
Matrix Recovery range Average
serum(n=5) 92-105% 98%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 85-97% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LAB7-2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-94% 85-97% 91-102% 81-90%
EDTA plasma(n=5) 78-92% 82-96% 86-99% 93-101%
Heparin plasma(n=5) 85-96% 86-98% 92-103% 87-93%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
松溪县| 兴安盟| 高邮市| 桑日县| 孟州市| 抚松县| 巩义市| 都安| 大田县| 股票| 新晃| 涿鹿县| 大兴区| 抚州市| 蒲江县| 环江| 澳门| 榕江县| 巫山县| 中宁县| 桑日县| 濮阳市| 阿巴嘎旗| 镇巴县| 德庆县| 岑溪市| 韩城市| 盘山县| 枞阳县| 黑龙江省| 古丈县| 沽源县| 林周县| 英德市| 台安县| 五家渠市| 凉山| 利川市| 师宗县| 屏东市| 横山县|