免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人60kD熱休克蛋白(HSPD1)酶聯(lián)免疫吸附檢測試劑盒
ELK1613
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human HSPD1(Heat Shock 60kD Protein 1, Chaperonin) ELISA Kit
Reactivity: Human
Alternative Names: HSP60; GROEL; CPN60; HuCHA60; Heat Shock Protein 60; Spastic Paraplegia 13,Autosomal Dominant; 60 kDa chaperonin; Mitochondrial matrix protein P1; P60 lymphocyte protein
Assay Type: Sandwich
Sensitivity: 0.58 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Tumor immunity;
Uniprot ID: P10809
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HSPD1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HSPD1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HSPD1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HSPD1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
100.00 1.972 1.879
50.00 1.507 1.414
25.00 1.193 1.100
12.50 0.796 0.703
6.25 0.576 0.483
3.13 0.385 0.292
1.57 0.235 0.142
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HSPD1 and the recovery rates were calculated by comparing the measured value to the expected amount of HSPD1 in samples.
Matrix Recovery range Average
serum(n=5) 95-107% 101%
EDTA plasma(n=5) 84-97% 91%
Heparin plasma(n=5) 82-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HSPD1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-101% 86-97% 88-95%
EDTA plasma(n=5) 85-92% 79-96% 95-103% 87-98%
Heparin plasma(n=5) 88-97% 96-103% 86-92% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
富平县| 宜兴市| 都昌县| 香格里拉县| 永泰县| 永州市| 太和县| 托里县| 涟源市| 车致| 聊城市| 尚义县| 湖北省| 大埔县| 马公市| 海伦市| 富平县| 贵阳市| 北宁市| 黎平县| 西城区| 永和县| 体育| 大埔县| 石首市| 万全县| 收藏| 长葛市| 河津市| 增城市| 萝北县| 炉霍县| 牡丹江市| 常州市| 耿马| 新昌县| 南乐县| 达孜县| 平江县| 太保市| 桂林市|