免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠60kD熱休克蛋白(HSPD1)酶聯(lián)免疫吸附檢測試劑盒
ELK1614
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat HSPD1(Heat Shock 60kD Protein 1, Chaperonin) ELISA Kit
Reactivity: Rat
Alternative Names: HSP60; GROEL; CPN60; HuCHA60; Heat Shock Protein 60; Spastic Paraplegia 13,Autosomal Dominant; 60 kDa chaperonin; Mitochondrial matrix protein P1; P60 lymphocyte protein
Assay Type: Sandwich
Sensitivity: 0.65 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Assay Length: 3.5h
Research Area: Signal transduction;Tumor immunity;
Uniprot ID: P63039
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat HSPD1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat HSPD1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat HSPD1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat HSPD1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
100.00 1.946 1.850
50.00 1.528 1.432
25.00 1.282 1.186
12.50 0.864 0.768
6.25 0.535 0.439
3.13 0.389 0.293
1.57 0.221 0.125
0.00 0.096 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HSPD1 and the recovery rates were calculated by comparing the measured value to the expected amount of HSPD1 in samples.
Matrix Recovery range Average
serum(n=5) 78-93% 85%
EDTA plasma(n=5) 90-105% 97%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HSPD1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 80-101% 87-96% 96-105% 95-103%
EDTA plasma(n=5) 85-93% 79-96% 93-106% 87-99%
Heparin plasma(n=5) 88-98% 87-103% 89-97% 85-94%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
河西区| 乐清市| 舟山市| 新闻| 许昌市| 会同县| 双流县| 汉川市| 榆中县| 北碚区| 嘉鱼县| 泰来县| 台湾省| 岑溪市| 德保县| 嵊州市| 怀远县| 买车| 壶关县| 大余县| 嘉义县| 天门市| 昌黎县| 苍梧县| 元氏县| 房产| 中卫市| 东光县| 赣州市| 宿迁市| 乌兰县| 东阿县| 苏尼特右旗| 泸定县| 四子王旗| 册亨县| 平江县| 巧家县| 渑池县| 松江区| 包头市|