免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人表面活性物質(zhì)關(guān)聯(lián)蛋白A(SPA)酶聯(lián)免疫吸附檢測試劑盒
ELK1644
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human SPA(Surfactant Associated Protein A) ELISA Kit
Reactivity: Human
Alternative Names: PRL; SFTPA; PSAP; PSPA; SFTP; SFTPA1; COLEC4; PSP-A; SFTP1; SFTPA1B; SP-A1; Collectin-4; Alveolar proteinosis protein; 35 kDa pulmonary surfactant-associated protein
Assay Type: Sandwich
Sensitivity: 17.43 pg/mL
Standard: 3000 pg/mL
Detection Range: 46.88-3000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, lung lavage fluid, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;Pulmonology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human SPA. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human SPA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human SPA, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SPA in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
3000.00 2.058 1.972
1500.00 1.472 1.386
750.00 1.183 1.097
375.00 0.883 0.797
187.50 0.509 0.423
93.75 0.354 0.268
46.88 0.302 0.216
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SPA and the recovery rates were calculated by comparing the measured value to the expected amount of SPA in samples.
Matrix Recovery range Average
serum(n=5) 78-96% 87%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 82-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SPA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 93-104% 83-96% 95-103% 88-95%
EDTA plasma(n=5) 86-94% 93-102% 87-96% 92-105%
Heparin plasma(n=5) 89-102% 92-101% 88-102% 87-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
同仁县| 桂阳县| 遂平县| 清流县| 公主岭市| 略阳县| 阳泉市| 宁陵县| 太和县| 囊谦县| 湄潭县| 广宗县| 盘山县| 贵溪市| 盖州市| 望都县| 河南省| 南投县| 靖州| 南汇区| 沐川县| 定南县| 平舆县| 大渡口区| 攀枝花市| 高州市| 临潭县| 涡阳县| 武穴市| 朝阳区| 乐安县| 武清区| 灵璧县| 伊金霍洛旗| 汕头市| 雅安市| 湖北省| 格尔木市| 汾阳市| 石城县| 昌图县|