免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人蛋白激酶Cε(PKCe)酶聯(lián)免疫吸附檢測試劑盒
ELK1647
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human PKCe(Protein Kinase C Epsilon) ELISA Kit
Reactivity: Human
Alternative Names: PKC-E; PRKCE; PRKC-E; NPKC-Epsilon
Assay Type: Sandwich
Sensitivity: 0.54 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Enzyme & Kinase;Apoptosis;Endocrinology;Cardiovascular biology;
Uniprot ID: Q02156
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PKCe. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human PKCe. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human PKCe, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PKCe in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
100.00 2.154 2.057
50.00 1.593 1.496
25.00 1.073 0.976
12.50 0.839 0.742
6.25 0.517 0.420
3.13 0.357 0.260
1.57 0.232 0.135
0.00 0.097 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PKCe and the recovery rates were calculated by comparing the measured value to the expected amount of PKCe in samples.
Matrix Recovery range Average
serum(n=5) 88-102% 95%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 82-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PKCe and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 92-101% 82-98% 89-97% 85-93%
EDTA plasma(n=5) 86-97% 93-105% 82-93% 95-104%
Heparin plasma(n=5) 82-96% 85-98% 95-104% 82-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
肥乡县| 郸城县| 阳曲县| 深泽县| 商丘市| 阜宁县| 云林县| 托里县| 武安市| 东方市| 新郑市| 湖北省| 三亚市| 萍乡市| 攀枝花市| 永仁县| 临洮县| 扎囊县| 平泉县| 武隆县| 巴彦淖尔市| 东安县| 商南县| 和顺县| 合川市| 维西| 三都| 邢台市| 邢台市| 建宁县| 莱芜市| 昆明市| 湟中县| 陈巴尔虎旗| 汉寿县| 桂林市| 肇庆市| 金堂县| 宽城| 宜川县| 红安县|