免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠補(bǔ)體成分4a(C4a)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1655
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse C4a(Complement Component 4a) ELISA Kit
Reactivity: Mouse
Alternative Names: C4a anaphylatoxin
Assay Type: Sandwich
Sensitivity: 11.9 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Immune molecule;Endocrinology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse C4a. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse C4a. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse C4a, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse C4a in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2000.00 2.079 1.986
1000.00 1.556 1.463
500.00 1.128 1.035
250.00 0.901 0.808
125.00 0.614 0.521
62.50 0.256 0.163
31.25 0.156 0.063
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant C4a and the recovery rates were calculated by comparing the measured value to the expected amount of C4a in samples.
Matrix Recovery range Average
serum(n=5) 80-93% 86%
EDTA plasma(n=5) 93-107% 100%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of C4a and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-90% 83-96% 95-102% 88-95%
EDTA plasma(n=5) 86-94% 93-102% 89-97% 85-94%
Heparin plasma(n=5) 79-96% 85-99% 79-93% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
三亚市| 华池县| 正安县| 新巴尔虎左旗| 祥云县| 麻阳| 鄂托克前旗| 萍乡市| 那坡县| 宣汉县| 宁津县| 拉孜县| 微山县| 花垣县| 岐山县| 乌鲁木齐县| 长武县| 西贡区| 奇台县| 卓资县| 丰台区| 平潭县| 婺源县| 玛多县| 封丘县| 山阴县| 孝感市| 光泽县| 利川市| 玛纳斯县| 定兴县| 河西区| 宁海县| 启东市| 金坛市| 福安市| 灌南县| 平谷区| 蒲江县| 临泽县| 舒兰市|