免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠食欲素A(OXA)酶聯(lián)免疫吸附檢測試劑盒
ELK1663
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Rat OXA(Orexin A) ELISA Kit
Reactivity: Rat
Alternative Names: Hypocretin-1
Assay Type: Competitive Inhibition
Sensitivity: 4.59 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Neuro science;Gastroenterology;Hormone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat OXA protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat OXA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat OXA in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 0.195
500.00 0.467
250.00 0.793
125.00 0.997
62.50 1.258
31.25 1.596
15.63 1.887
0.00 2.219

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant OXA and the recovery rates were calculated by comparing the measured value to the expected amount of OXA in samples.
Matrix Recovery range Average
serum(n=5) 87-95% 91%
EDTA plasma(n=5) 78-92% 85%
Heparin plasma(n=5) 92-106% 99%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of OXA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-103% 85-93% 89-97% 95-102%
EDTA plasma(n=5) 85-94% 93-101% 87-98% 89-102%
Heparin plasma(n=5) 88-97% 85-101% 86-98% 96-107%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
孝感市| 陆河县| 双柏县| 雅江县| 昌乐县| 广东省| 南木林县| 天柱县| 静乐县| 平安县| 万安县| 璧山县| 松滋市| 南陵县| 通榆县| 德令哈市| 建宁县| 平乡县| 林芝县| 凌云县| 寻甸| 拜泉县| 桂平市| 玛沁县| 察隅县| 五寨县| 清河县| 长顺县| 吉安县| 嫩江县| 甘谷县| 广昌县| 西城区| 防城港市| 宣化县| 巩义市| 肇庆市| 东山县| 江陵县| 原阳县| 昭苏县|