免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠解整合素金屬蛋白酶8(ADAM8)酶聯(lián)免疫吸附檢測試劑盒
ELK1696
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse ADAM8(A Disintegrin And Metalloprotease 8) ELISA Kit
Reactivity: Mouse
Alternative Names: CD156-A; MS2; CD156a; Disintegrin and metalloproteinase domain-containing protein 8
Assay Type: Sandwich
Sensitivity: 3.1 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Tumor immunity;Immune molecule;Neuro science;
Uniprot ID: Q05910
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse ADAM8. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse ADAM8. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse ADAM8, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse ADAM8 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
500.00 2.126 2.058
250.00 1.602 1.534
125.00 1.183 1.115
62.50 0.872 0.804
31.25 0.509 0.441
15.63 0.372 0.304
7.82 0.225 0.157
0.00 0.068 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ADAM8 and the recovery rates were calculated by comparing the measured value to the expected amount of ADAM8 in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 96-108% 102%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ADAM8 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 92-105% 82-92% 86-94% 81-95%
EDTA plasma(n=5) 92-104% 86-98% 80-93% 89-97%
Heparin plasma(n=5) 85-90% 83-96% 95-102% 88-95%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
津南区| 蒙城县| 顺义区| 邹平县| 柘荣县| 海南省| 商城县| 堆龙德庆县| 泽州县| 克山县| 高州市| 赫章县| 浪卡子县| 喀喇沁旗| 祁东县| 汉川市| 古丈县| 喀喇沁旗| 察雅县| 湘潭市| 湘潭市| 安国市| 凭祥市| 甘德县| 北票市| 长治市| 荥经县| 木兰县| 军事| 朝阳区| 永寿县| 盖州市| 通化县| 尚志市| 买车| 麦盖提县| 德保县| 北辰区| 石柱| 浪卡子县| 潼关县|