免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠乳鐵傳遞蛋白(LTF)酶聯(lián)免疫吸附檢測試劑盒
ELK1697
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat LTF(Lactoferrin) ELISA Kit
Reactivity: Rat
Alternative Names: HLF2; LF; GIG12; Lactotransferrin; Growth-inhibiting protein 12; Talalactoferrin; Lfcin-H; Kaliocin-1
Assay Type: Sandwich
Sensitivity: 2.9 ng/mL
Standard: 400 ng/mL
Detection Range: 6.25-400 ng/mL
Sample Type: Serum, plasma and other biological fluids.
Assay Length: 3.5h
Research Area: Tumor immunity;Infection immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat LTF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat LTF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat LTF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat LTF in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
400.00 2.207 2.118
200.00 1.563 1.474
100.00 1.186 1.097
50.00 0.882 0.793
25.00 0.527 0.438
12.50 0.325 0.236
6.25 0.206 0.117
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant LTF and the recovery rates were calculated by comparing the measured value to the expected amount of LTF in samples.
Matrix Recovery range Average
serum(n=5) 80-97% 88%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 88-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LTF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 83-103% 82-93% 86-95% 81-96%
EDTA plasma(n=5) 92-105% 92-101% 80-94% 86-101%
Heparin plasma(n=5) 85-94% 87-101% 89-99% 85-95%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
江阴市| 东港市| 淮滨县| 平安县| 澄江县| 北辰区| 古田县| 天峨县| 永善县| 大化| 宁蒗| 汾阳市| 贵德县| 平阴县| 龙井市| 疏勒县| 连州市| 邵武市| 苍山县| 平江县| 宜春市| 邳州市| 同江市| 伊宁县| 安义县| 乐都县| 马尔康县| 辽宁省| 鄯善县| 政和县| 罗定市| 满城县| 七台河市| 襄樊市| 松滋市| 察隅县| 道真| 东乌珠穆沁旗| 罗源县| 黄浦区| 威信县|