免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠趨化因子C-X-C-基元配體16(CXCL16)酶聯(lián)免疫吸附檢測試劑盒
ELK1706
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat CXCL16(Chemokine C-X-C-Motif Ligand 16) ELISA Kit
Reactivity: Rat
Alternative Names: SR-PSOX; CXCLG16; SRPSOX; Scavenger receptor for phosphatidylserine and oxidized low density lipoprotein; Small-inducible cytokine B16
Assay Type: Sandwich
Sensitivity: 0.055 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;
Uniprot ID: Q6AXU5
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat CXCL16. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat CXCL16. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat CXCL16, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat CXCL16 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.201 2.098
5.00 1.717 1.614
2.50 1.116 1.013
1.25 0.896 0.793
0.63 0.582 0.479
0.32 0.318 0.215
0.16 0.215 0.112
0.00 0.103 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CXCL16 and the recovery rates were calculated by comparing the measured value to the expected amount of CXCL16 in samples.
Matrix Recovery range Average
serum(n=5) 78-92% 85%
EDTA plasma(n=5) 85-99% 92%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CXCL16 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 81-94% 96-105% 92-103% 82-96%
EDTA plasma(n=5) 87-96% 91-101% 87-98% 89-103%
Heparin plasma(n=5) 84-94% 85-103% 94-105% 92-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
青铜峡市| 淮阳县| 南宁市| 垦利县| 资溪县| 陆河县| 枣强县| 茂名市| 红桥区| 纳雍县| 汾阳市| 自治县| 仁布县| 双流县| 林西县| 钟祥市| 芜湖县| 芜湖县| 绥宁县| 琼海市| 昌吉市| 乐业县| 闸北区| 个旧市| 米林县| 视频| 隆德县| 吉水县| 炉霍县| 巴林左旗| 滦平县| 巴东县| 南投县| 罗定市| 日土县| 乐清市| 阜新市| 苏尼特左旗| 杭锦旗| 长沙市| 岫岩|