免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人粘蛋白3(MUC3)酶聯(lián)免疫吸附檢測試劑盒
ELK1737
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human MUC3(Mucin 3) ELISA Kit
Reactivity: Human
Alternative Names: MUC3A; Mucin 3A,Intestinal
Assay Type: Sandwich
Sensitivity: 0.06 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Infection immunity;Pulmonology;
Uniprot ID: Q02505
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MUC3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MUC3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MUC3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MUC3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.135 2.039
5.00 1.562 1.466
2.50 1.174 1.078
1.25 0.963 0.867
0.63 0.593 0.497
0.32 0.324 0.228
0.16 0.226 0.130
0.00 0.096 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MUC3 and the recovery rates were calculated by comparing the measured value to the expected amount of MUC3 in samples.
Matrix Recovery range Average
serum(n=5) 95-107% 101%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 85-97% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MUC3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 80-92% 86-102% 87-103% 85-101%
EDTA plasma(n=5) 85-97% 93-101% 97-103% 91-99%
Heparin plasma(n=5) 81-97% 88-102% 85-93% 83-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
绍兴县| 灌南县| 司法| 桂阳县| 白山市| 图木舒克市| 垣曲县| 游戏| 全椒县| 武城县| 丹东市| 淅川县| 射阳县| 遂川县| 诸城市| 苏尼特左旗| 富川| 鄂伦春自治旗| 甘泉县| 务川| 察哈| 平南县| 松溪县| 公主岭市| 东源县| 沈丘县| 武邑县| 沙洋县| 康马县| 元氏县| 浮梁县| 东台市| 收藏| 雷波县| 横峰县| 梅州市| 柳江县| 彰化市| 武胜县| 红桥区| 富锦市|