免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人磷脂酰肌醇蛋白聚糖1(GPC1)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1738
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human GPC1(Glypican 1) ELISA Kit
Reactivity: Human
Alternative Names: Glypican Proteoglycan 1; Secreted glypican-1
Assay Type: Sandwich
Sensitivity: 0.3 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Pulmonology;Hepatology;
Uniprot ID: P35052
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GPC1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GPC1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human GPC1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GPC1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
50.00 1.952 1.870
25.00 1.587 1.505
12.50 1.197 1.115
6.25 0.882 0.800
3.13 0.567 0.485
1.57 0.329 0.247
0.79 0.234 0.152
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GPC1 and the recovery rates were calculated by comparing the measured value to the expected amount of GPC1 in samples.
Matrix Recovery range Average
serum(n=5) 95-107% 101%
EDTA plasma(n=5) 85-95% 90%
Heparin plasma(n=5) 79-93% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GPC1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-102% 87-96% 92-101% 83-96%
EDTA plasma(n=5) 98-107% 93-102% 80-93% 91-100%
Heparin plasma(n=5) 92-105% 85-101% 85-94% 87-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
江永县| 平顺县| 北票市| 平湖市| 当阳市| 上犹县| 清新县| 娄烦县| 桐梓县| 佛坪县| 金湖县| 清水县| 烟台市| 林口县| 亳州市| 辽源市| 滦平县| 扎兰屯市| 平凉市| 武清区| 剑川县| 林州市| 武邑县| 孝义市| 万荣县| 新晃| 平安县| 宁阳县| 罗平县| 女性| 叶城县| 徐州市| 平果县| 宁国市| 津南区| 台南市| 南和县| 五原县| 东城区| 孟村| 股票|