免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人生長激素受體(GHR)酶聯(lián)免疫吸附檢測試劑盒
ELK1741
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human GHR(Growth Hormone Receptor) ELISA Kit
Reactivity: Human
Alternative Names: GHBP; Somatotropin receptor; Growth hormone-binding protein; Serum-binding protein
Assay Type: Sandwich
Sensitivity: 0.54 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Endocrinology;Hormone metabolism;
Uniprot ID: P10912
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GHR. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GHR. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human GHR, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GHR in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
100.00 2.075 1.980
50.00 1.502 1.407
25.00 1.183 1.088
12.50 0.883 0.788
6.25 0.496 0.401
3.13 0.319 0.224
1.57 0.196 0.101
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GHR and the recovery rates were calculated by comparing the measured value to the expected amount of GHR in samples.
Matrix Recovery range Average
serum(n=5) 79-97% 88%
EDTA plasma(n=5) 83-95% 89%
Heparin plasma(n=5) 88-102% 95%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GHR and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 83-97% 81-103% 89-101% 81-98%
EDTA plasma(n=5) 95-104% 93-105% 82-101% 91-103%
Heparin plasma(n=5) 83-95% 88-102% 85-97% 80-92%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
新宁县| 鸡泽县| 图们市| 错那县| 勐海县| 板桥市| 托克逊县| 桑植县| 临安市| 柯坪县| 临朐县| 江山市| 河北省| 玉龙| 新乡市| 大关县| 临泽县| 竹北市| 潞城市| 本溪| 临泽县| 长兴县| 西充县| 大同市| 芦溪县| 凯里市| 沛县| 南陵县| 建昌县| 襄垣县| 团风县| 江孜县| 阿拉善盟| 福建省| 汤原县| 新闻| 日喀则市| 左贡县| 北宁市| 南部县| 沭阳县|