免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人泛素連接酶E3A(UBE3A)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1751
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human UBE3A(Ubiquitin Protein Ligase E3A) ELISA Kit
Reactivity: Human
Alternative Names: ANCR; AS; E6-AP; EPVE6AP; HPVE6A; Papilloma Virus E6-Associated,Angelman Syndrome; Oncogenic protein-associated protein E6-AP; Renal carcinoma antigen NY-REN-54
Assay Type: Sandwich
Sensitivity: 0.122 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Developmental science;
Uniprot ID: Q05086
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human UBE3A. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human UBE3A. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human UBE3A, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human UBE3A in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.126 2.027
10.00 1.527 1.428
5.00 1.121 1.022
2.50 0.975 0.876
1.25 0.547 0.448
0.63 0.324 0.225
0.32 0.196 0.097
0.00 0.099 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant UBE3A and the recovery rates were calculated by comparing the measured value to the expected amount of UBE3A in samples.
Matrix Recovery range Average
serum(n=5) 97-107% 102%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 82-94% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of UBE3A and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 92-105% 95-107% 82-96%
EDTA plasma(n=5) 79-91% 89-103% 82-95% 86-99%
Heparin plasma(n=5) 87-96% 91-101% 87-98% 89-103%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
库尔勒市| 宝丰县| 和田县| 平潭县| 木里| 册亨县| 社会| 延川县| 观塘区| 兴山县| 海丰县| 博爱县| 犍为县| 遂宁市| 乐昌市| 吴江市| 囊谦县| 登封市| 仁寿县| 讷河市| 宁远县| 昆山市| 辉南县| 鹿邑县| 桐乡市| 弥渡县| 都兰县| 温泉县| 汉寿县| 滨州市| 湖南省| 镇赉县| 乐清市| 莱西市| 定安县| 皮山县| 泽库县| 昌图县| 安平县| 玉林市| 颍上县|