免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人促胰液素(SCT)酶聯(lián)免疫吸附檢測試劑盒
ELK1753
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human SCT(Secretin) ELISA Kit
Reactivity: Human
Alternative Names: Secretin
Assay Type: Competitive Inhibition
Sensitivity: 7.01 pg/mL
Standard: 1500 pg/mL
Detection Range: 23.44-1500 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Endocrinology;Hepatology;Hormone metabolism;
Uniprot ID: P09683
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human SCT. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human SCT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SCT in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1500.00 0.227
750.00 0.386
375.00 0.611
187.50 0.833
93.75 1.156
46.88 1.511
23.44 1.789
0.00 2.211

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SCT and the recovery rates were calculated by comparing the measured value to the expected amount of SCT in samples.
Matrix Recovery range Average
serum(n=5) 86-99% 92%
EDTA plasma(n=5) 89-103% 96%
Heparin plasma(n=5) 78-96% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SCT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-104% 87-96% 85-93% 82-90%
EDTA plasma(n=5) 85-101% 78-96% 79-98% 93-102%
Heparin plasma(n=5) 88-101% 90-98% 92-106% 85-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
宽城| 铜山县| 景洪市| 青州市| 长葛市| 东港市| 彭山县| 德兴市| 镇沅| 屯门区| 蕲春县| 新晃| 淄博市| 浙江省| 北辰区| 延边| 临武县| 巨野县| 红桥区| 马公市| 柞水县| 东山县| 陕西省| 龙江县| 蒙阴县| 平乐县| 武威市| 赤壁市| 涟源市| 个旧市| 屏山县| 商洛市| 吴旗县| 资溪县| 大宁县| 吴忠市| 文山县| 乌拉特前旗| 崇仁县| 郑州市| 黄浦区|