免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人ⅡD組磷脂酶A2(PLA2G2D)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1754
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human PLA2G2D(Phospholipase A2, Group IID) ELISA Kit
Reactivity: Human
Alternative Names: PLA2G2D; sPLA2S; s-PLA2; sPLA2; SPLASH; Secreted Phospholipase A2; Phosphatidylcholine 2-acylhydrolase 2D; Secretory-type PLA, stroma-associated homolog
Assay Type: Sandwich
Sensitivity: 0.131 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Hepatology;
Uniprot ID: Q9UNK4
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PLA2G2D. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human PLA2G2D. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human PLA2G2D, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PLA2G2D in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.126 2.043
10.00 1.673 1.590
5.00 1.087 1.004
2.50 0.795 0.712
1.25 0.509 0.426
0.63 0.357 0.274
0.32 0.235 0.152
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PLA2G2D and the recovery rates were calculated by comparing the measured value to the expected amount of PLA2G2D in samples.
Matrix Recovery range Average
serum(n=5) 92-107% 99%
EDTA plasma(n=5) 85-98% 91%
Heparin plasma(n=5) 81-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PLA2G2D and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 83-96% 95-107% 87-102%
EDTA plasma(n=5) 82-94% 85-96% 78-90% 91-99%
Heparin plasma(n=5) 90-99% 83-97% 81-103% 89-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
陇西县| 蒲江县| 柳江县| 英吉沙县| 墨玉县| 抚顺县| 阿拉善盟| 佛山市| 郎溪县| 雷州市| 横峰县| 彭阳县| 濮阳县| 旺苍县| 民乐县| 苍南县| 云安县| 灵宝市| 宁都县| 读书| 韩城市| 信阳市| 柳林县| 桑植县| 武汉市| 大名县| 保靖县| 拉萨市| 灌云县| 神农架林区| 洛宁县| 麦盖提县| 望都县| 连城县| 涟源市| 黄冈市| 湘阴县| 汉源县| 灵宝市| 尉犁县| 财经|