免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠凝血因子ⅩⅢ(F13)酶聯(lián)免疫吸附檢測試劑盒
ELK1768
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat F13(Coagulation Factor XIII) ELISA Kit
Reactivity: Rat
Alternative Names: FXIII; Fibrin Stabilizing Factor
Assay Type: Sandwich
Sensitivity: 0.53 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: Plasma.
Assay Length: 3.5h
Research Area: Metabolic pathway;Hematology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat F13. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat F13. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat F13, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat F13 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
100.00 2.168 2.060
50.00 1.700 1.592
25.00 1.142 1.034
12.50 0.855 0.747
6.25 0.576 0.468
3.13 0.387 0.279
1.57 0.226 0.118
0.00 0.108 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant F13 and the recovery rates were calculated by comparing the measured value to the expected amount of F13 in samples.
Matrix Recovery range Average
serum(n=5) 79-97% 88%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 84-98% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of F13 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 83-94% 80-92% 86-102% 87-103%
EDTA plasma(n=5) 92-105% 85-101% 85-94% 87-96%
Heparin plasma(n=5) 96-101% 85-92% 79-96% 89-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
双鸭山市| 巫山县| 泰兴市| 鹿邑县| 顺平县| 青海省| 三河市| 洛扎县| 水城县| 塔河县| 遂平县| 都兰县| 玉环县| 信丰县| 兴文县| 隆子县| 安徽省| 临西县| 镇沅| 汤原县| 镇沅| 达拉特旗| 南康市| 南通市| 濮阳县| 林周县| 怀柔区| 灵石县| 苏州市| 穆棱市| 延吉市| 龙江县| 阳曲县| 阜康市| 许昌县| 当阳市| 新宾| 额尔古纳市| 沭阳县| 芜湖市| 兴义市|