免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人O-6-甲基鳥嘌呤DNA甲基轉(zhuǎn)移酶(MGMT)酶聯(lián)免疫吸附檢測試劑盒
ELK1782
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human MGMT(O-6-Methylguanine DNA Methyltransferase) ELISA Kit
Reactivity: Human
Alternative Names: Methylated-DNA--Protein-Cysteine Methyltransferase; 6-O-methylguanine-DNA methyltransferase; Methylated-DNA--protein-cysteine methyltransferase
Assay Type: Sandwich
Sensitivity: 0.053 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Enzyme & Kinase;Tumor immunity;
Uniprot ID: P16455
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MGMT. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MGMT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MGMT, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MGMT in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.154 2.068
5.00 1.630 1.544
2.50 1.174 1.088
1.25 0.882 0.796
0.63 0.527 0.441
0.32 0.372 0.286
0.16 0.187 0.101
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MGMT and the recovery rates were calculated by comparing the measured value to the expected amount of MGMT in samples.
Matrix Recovery range Average
serum(n=5) 90-107% 98%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 80-95% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MGMT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-102% 82-94% 85-96% 78-90%
EDTA plasma(n=5) 92-106% 93-105% 85-99% 90-99%
Heparin plasma(n=5) 88-104% 84-98% 95-105% 88-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
泰顺县| 胶州市| 嘉定区| 金湖县| 泰顺县| 肇源县| 平邑县| 雷州市| 定兴县| 涞水县| 泊头市| 凤凰县| 商河县| 新巴尔虎右旗| 阳新县| 阿拉善右旗| 武隆县| 东乡族自治县| 宝兴县| 萨迦县| 龙里县| 高碑店市| 上蔡县| 肃北| 汨罗市| 吉水县| 科技| 和硕县| 庐江县| 年辖:市辖区| 横山县| 靖远县| 鄂托克旗| 方正县| 贵溪市| 长乐市| 阿鲁科尔沁旗| 临湘市| 万山特区| 静宁县| 太和县|