免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人白介素29(IL29)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1784
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human IL29(Interleukin 29) ELISA Kit
Reactivity: Human
Alternative Names: IL-29;FNL1; Interferon,Lambda 1; Cytokine Zcyto21
Assay Type: Sandwich
Sensitivity: 2.6 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Uniprot ID: Q8IU54
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IL29. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human IL29. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human IL29, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IL29 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
500.00 2.035 1.946
250.00 1.717 1.628
125.00 1.035 0.946
62.50 0.782 0.693
31.25 0.469 0.380
15.63 0.315 0.226
7.82 0.206 0.117
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant IL29 and the recovery rates were calculated by comparing the measured value to the expected amount of IL29 in samples.
Matrix Recovery range Average
serum(n=5) 96-107% 101%
EDTA plasma(n=5) 90-105% 97%
Heparin plasma(n=5) 85-97% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IL29 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-105% 84-98% 95-102% 88-106%
EDTA plasma(n=5) 87-94% 91-104% 95-107% 82-96%
Heparin plasma(n=5) 81-94% 93-107% 93-102% 91-105%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
临高县| 清丰县| 西吉县| 昌乐县| 正安县| 丰镇市| 治县。| 灌云县| 开化县| 新兴县| 扎兰屯市| 富源县| 安乡县| 湾仔区| 凤城市| 辽宁省| 宝鸡市| 牙克石市| 米林县| 赤峰市| 太原市| 东港市| SHOW| 彭水| 德安县| 湖州市| 佛冈县| 石楼县| 冕宁县| 松阳县| 手游| 虎林市| 宁河县| 花莲县| 柳州市| 江华| 清远市| 澜沧| 涞源县| 惠安县| 习水县|