免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人CD14分子(CD14)酶聯(lián)免疫吸附檢測試劑盒
ELK1787
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human CD14(Cluster Of Differentiation 14) ELISA Kit
Reactivity: Human
Alternative Names: Monocyte differentiation antigen CD14; Myeloid cell-specific leucine-rich glycoprotein
Assay Type: Sandwich
Sensitivity: 0.335 ng/mL
Standard: 60 ng/mL
Detection Range: 0.94-60 ng/mL
Sample Type: serum, plasma, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: CD & Adhesion molecule;Tumor immunity;Infection immunity;Immune molecule;
Uniprot ID: P08571
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CD14. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CD14. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CD14, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CD14 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
60.00 2.266 2.168
30.00 1.711 1.613
15.00 1.282 1.184
7.50 0.933 0.835
3.75 0.468 0.370
1.88 0.317 0.219
0.94 0.175 0.077
0.00 0.098 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CD14 and the recovery rates were calculated by comparing the measured value to the expected amount of CD14 in samples.
Matrix Recovery range Average
serum(n=5) 80-92% 86%
EDTA plasma(n=5) 85-99% 92%
Heparin plasma(n=5) 83-97% 90%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CD14 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 83-92% 92-96% 86-98% 95-101%
EDTA plasma(n=5) 89-101% 79-92% 82-93% 83-97%
Heparin plasma(n=5) 82-103% 81-91% 85-101% 81-90%