免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人精氨酸酶1(ARG1)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1790
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human ARG1(Arginase I) ELISA Kit
Reactivity: Human
Alternative Names: ARG1; Arginase I; Liver Arginase; ARG; Arginase
Assay Type: Sandwich
Sensitivity: 1.21 ng/mL
Standard: 200 ng/mL
Detection Range: 3.13-200 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Tumor immunity;Infection immunity;Hepatology;
Uniprot ID: P05089
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ARG1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ARG1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ARG1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ARG1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
200.00 2.258 2.164
100.00 1.653 1.559
50.00 1.116 1.022
25.00 0.805 0.711
12.50 0.475 0.381
6.25 0.308 0.214
3.13 0.256 0.162
0.00 0.094 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ARG1 and the recovery rates were calculated by comparing the measured value to the expected amount of ARG1 in samples.
Matrix Recovery range Average
serum(n=5) 81-95% 88%
EDTA plasma(n=5) 90-105% 97%
Heparin plasma(n=5) 84-97% 90%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ARG1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 85-96% 93-102% 95-104%
EDTA plasma(n=5) 92-103% 81-92% 78-87% 91-99%
Heparin plasma(n=5) 92-104% 93-99% 87-953% 82-93%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
日照市| 饶平县| 云霄县| 鄢陵县| 三河市| 乌苏市| 视频| 金乡县| 临朐县| 洛浦县| 老河口市| 阿荣旗| 阳春市| 巴塘县| 菏泽市| 招远市| 江口县| 乐东| 叶城县| 蒙阴县| 边坝县| 龙川县| 青州市| 邵阳市| 合作市| 保靖县| 同心县| 新郑市| 乐山市| 黔南| 迁安市| 铅山县| 元朗区| 高陵县| 邢台市| 台北县| 宜昌市| 鄂州市| 焦作市| 育儿| 黔东|