免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人硫氧還蛋白結(jié)合蛋白2(TBP2)酶聯(lián)免疫吸附檢測試劑盒
ELK1796
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human TBP2(Thioredoxin Binding Protein 2) ELISA Kit
Reactivity: Human
Alternative Names: TXNIP; HHCPA78; THIF; VDUP1; Thioredoxin Interacting Protein; Vitamin D3-Upregulated Protein 1; Upregulated By 1,25-Dihydroxyvitamin D-3
Assay Type: Sandwich
Sensitivity: 0.058 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TBP2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TBP2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TBP2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TBP2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.054 1.965
5.00 1.527 1.438
2.50 1.251 1.162
1.25 0.896 0.807
0.63 0.453 0.364
0.32 0.369 0.280
0.16 0.236 0.147
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TBP2 and the recovery rates were calculated by comparing the measured value to the expected amount of TBP2 in samples.
Matrix Recovery range Average
serum(n=5) 80-93% 86%
EDTA plasma(n=5) 78-90% 84%
Heparin plasma(n=5) 85-97% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TBP2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-104% 97-106% 85-98% 81-92%
EDTA plasma(n=5) 87-103% 79-92% 86-99% 84-97%
Heparin plasma(n=5) 85-98% 97-104% 92-101% 82-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
务川| 苏尼特右旗| 韩城市| 吴堡县| 肃南| 山阴县| 沅陵县| 越西县| 大庆市| 宜宾县| 屏东市| 林西县| 水城县| 永川市| 临西县| 冕宁县| 商水县| 九寨沟县| 蒲江县| 威信县| 滨州市| 定州市| 蓬安县| 赤水市| 合阳县| 张家界市| 靖西县| 郑州市| 东兰县| 尼勒克县| 微博| 马关县| 宁武县| 亚东县| 瑞金市| 湖南省| 杨浦区| 东乡族自治县| 文山县| 宝鸡市| 济阳县|