Overview

Product name: Human NT(Neurotensin) ELISA Kit
Reactivity: Human
Alternative Names: NTS; NTS1; NmN-125; NN; Tail peptide Neuromedin N
Assay Type: Competitive Inhibition
Sensitivity: 14.2 pg/mL
Standard: 3000 pg/mL
Detection Range: 46.88-3000 pg/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 2h
Research Area: Reproductive science;Neuro science;Hormone metabolism;
Uniprot ID: P30990
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human NT. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human NT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human NT in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
3000.00 0.235
1500.00 0.389
750.00 0.655
375.00 0.856
187.50 1.225
93.75 1.596
46.88 1.761
0.00 2.325

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NT and the recovery rates were calculated by comparing the measured value to the expected amount of NT in samples.
Matrix Recovery range Average
serum(n=5) 95-108% 101%
EDTA plasma(n=5) 83-97% 90%
Heparin plasma(n=5) 80-97% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 90-99% 87-103% 78-91% 83-97%
EDTA plasma(n=5) 85-102% 83-96% 95-102% 87-98%
Heparin plasma(n=5) 89-97% 86-102% 94-106% 85-97%
關(guān)閉

在線咨詢(xún)

Online consultation

  • 在線咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
乌拉特后旗| 团风县| 乡宁县| 闵行区| 遂川县| 阿拉善右旗| 西吉县| 聂荣县| 佛坪县| 潢川县| 辉县市| 松滋市| 永嘉县| 上杭县| 英山县| 长丰县| 漳平市| 晋中市| 崇信县| 泰来县| 西丰县| 阿图什市| 威远县| 泉州市| 静宁县| 大关县| 元朗区| 利辛县| 嘉义县| 白河县| 新巴尔虎右旗| 常宁市| 三都| 沈丘县| 台北市| 五原县| 松溪县| 金秀| 商城县| 郑州市| 丰城市|