免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人毒蕈堿型膽堿受體M2(CHRM2)酶聯(lián)免疫吸附檢測試劑盒
ELK1807
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human CHRM2(Cholinergic Receptor, Muscarinic 2) ELISA Kit
Reactivity: Human
Alternative Names: CHR-M2; HM2; M-AChRM2; Muscarinic Acetylcholine Receptor M2; Cholinergic Receptor,Muscarinic 2
Assay Type: Sandwich
Sensitivity: 0.056 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Signal transduction;Cardiovascular biology;Neuro science;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CHRM2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CHRM2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CHRM2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CHRM2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 1.994 1.886
5.00 1.515 1.407
2.50 1.282 1.174
1.25 0.864 0.756
0.63 0.535 0.427
0.32 0.387 0.279
0.16 0.226 0.118
0.00 0.108 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CHRM2 and the recovery rates were calculated by comparing the measured value to the expected amount of CHRM2 in samples.
Matrix Recovery range Average
serum(n=5) 80-96% 88%
EDTA plasma(n=5) 82-98% 90%
Heparin plasma(n=5) 84-98% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CHRM2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-103% 80-96% 87-98% 85-92%
EDTA plasma(n=5) 89-97% 85-92% 95-103% 87-93%
Heparin plasma(n=5) 89-102% 97-103% 88-96% 95-101%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
杭州市| 航空| 镇巴县| 富川| 即墨市| 宁远县| 巴楚县| 桃园县| 东台市| 衡阳县| 海盐县| 运城市| 射洪县| 古田县| 巨野县| 安阳县| 吉林市| 江华| 启东市| 东平县| 河东区| 黑水县| 灵璧县| 高安市| 特克斯县| 云浮市| 当雄县| 延吉市| 龙胜| 三门峡市| 婺源县| 图木舒克市| 股票| 台前县| 田东县| 丰县| 宁德市| 隆昌县| 左云县| 瑞丽市| 石门县|