免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人胃泌素(GT)酶聯(lián)免疫吸附檢測試劑盒
ELK1814
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human GT(Gastrin) ELISA Kit
Reactivity: Human
Alternative Names: GAST; GAS; Gastrin component I; Big gastrin; Gastrin component II; Gastrin component III; Gastrin 17; Gastrin 34
Assay Type: Competitive Inhibition
Sensitivity: 4.21 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Metabolic pathway;Endocrinology;Gastroenterology;Hormone metabolism;
Uniprot ID: P01350
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human GT. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GT in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 0.215
500.00 0.334
250.00 0.524
125.00 0.731
62.50 0.977
31.25 1.572
15.63 1.786
0.00 2.236

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GT and the recovery rates were calculated by comparing the measured value to the expected amount of GT in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 86-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-104% 87-96% 89-101% 82-90%
EDTA plasma(n=5) 79-92% 95-103% 82-98% 85-97%
Heparin plasma(n=5) 87-102% 87-96% 92-101% 83-96%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
象州县| 恩施市| 长垣县| 琼中| 惠水县| 平凉市| 吉隆县| 浪卡子县| 凌海市| 鄂托克旗| 民和| 运城市| 台南市| 四平市| 徐闻县| 资阳市| 桦南县| 乾安县| 合江县| 营口市| 林西县| 册亨县| 榆树市| 秦安县| 庆安县| 邵东县| 长葛市| 高平市| 高唐县| 宜章县| 祁阳县| 剑阁县| 曲麻莱县| 西盟| 乌恰县| 达尔| 富阳市| 普格县| 清涧县| 慈溪市| 安庆市|