免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠環(huán)加氧酶1(PTGS1)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1859
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat PTGS1(Prostaglandin Endoperoxide Synthase 1) ELISA Kit
Reactivity: Rat
Alternative Names: COX1; COX3; PCOX1; PGG/HS; PGHS1; PHS1; PTGHS; Cyclooxygenase 1; Prostaglandin H2 Synthase 1; Prostaglandin G/H Synthase And Cyclooxygenase
Assay Type: Sandwich
Sensitivity: 0.244 ng/mL
Standard: 40 ng/mL
Detection Range: 0.63-40 ng/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Enzyme & Kinase;Tumor immunity;Infection immunity;
Uniprot ID: Q63921
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat PTGS1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat PTGS1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat PTGS1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat PTGS1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
40.00 2.156 2.061
20.00 1.755 1.660
10.00 1.102 1.007
5.00 0.837 0.742
2.50 0.474 0.379
1.25 0.325 0.230
0.63 0.193 0.098
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PTGS1 and the recovery rates were calculated by comparing the measured value to the expected amount of PTGS1 in samples.
Matrix Recovery range Average
serum(n=5) 80-92% 86%
EDTA plasma(n=5) 78-95% 86%
Heparin plasma(n=5) 80-96% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PTGS1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 90-96% 87-1028% 85-97%
EDTA plasma(n=5) 87-96% 86-98% 91-103% 87-90%
Heparin plasma(n=5) 87-98% 85-96% 92-102% 81-93%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
蒙城县| 康乐县| 凉城县| 睢宁县| 浙江省| 嘉祥县| 淳化县| 洛隆县| 武安市| 鹤庆县| 鄂尔多斯市| 应用必备| 邢台市| 大荔县| 仁怀市| 龙山县| 申扎县| 西乌| 米林县| 台州市| 六盘水市| 崇信县| 通辽市| 井陉县| 景宁| 交口县| 孟连| 固始县| 镇江市| 鸡西市| 广德县| 麻江县| 安吉县| 榆林市| 黄龙县| 曲水县| 平远县| 冷水江市| 巫山县| 辉南县| 高要市|