免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人骨形成蛋白6(BMP6)酶聯(lián)免疫吸附檢測試劑盒
ELK1860
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Human BMP6(Bone Morphogenetic Protein 6) ELISA Kit
Reactivity: Human
Alternative Names: VGR; VGR1; Vegetal Related Growth Factor(TGFB-Related); VG-1-related protein
Assay Type: Sandwich
Sensitivity: 24.4 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Developmental science;
Uniprot ID: P22004
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human BMP6. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human BMP6. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human BMP6, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human BMP6 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.328 2.246
500.00 1.745 1.663
250.00 1.032 0.950
125.00 0.856 0.774
62.50 0.547 0.465
31.25 0.300 0.218
15.63 0.170 0.088
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant BMP6 and the recovery rates were calculated by comparing the measured value to the expected amount of BMP6 in samples.
Matrix Recovery range Average
serum(n=5) 86-99% 92%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 90-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of BMP6 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-102% 87-96% 78-92% 85-97%
EDTA plasma(n=5) 88-104% 86-102% 79-93% 89-97%
Heparin plasma(n=5) 85-94% 87-101% 82-95% 82-93%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
天长市| 沙湾县| 恩平市| 江都市| 康保县| 瑞丽市| 正定县| 天峨县| 西华县| 湘西| 井研县| 门头沟区| 外汇| 赫章县| 岚皋县| 自治县| 罗江县| 钟祥市| 根河市| 文安县| 宁南县| 荔波县| 岐山县| 通道| 四川省| 长兴县| 江西省| 华蓥市| 仙桃市| 渝北区| 霍邱县| 合水县| 西城区| 论坛| 云林县| 顺昌县| 永靖县| 克拉玛依市| 阳东县| 桐庐县| 临湘市|