免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠骨形成蛋白6(BMP6)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1861
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat BMP6(Bone Morphogenetic Protein 6) ELISA Kit
Reactivity: Rat
Alternative Names: VGR; VGR1; Vegetal Related Growth Factor(TGFB-Related); VG-1-related protein
Assay Type: Sandwich
Sensitivity: 12.8 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Developmental science;
Uniprot ID: Q04906
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat BMP6. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat BMP6. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat BMP6, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat BMP6 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2000.00 1.964 1.882
1000.00 1.616 1.534
500.00 1.043 0.961
250.00 0.869 0.787
125.00 0.548 0.466
62.50 0.335 0.253
31.25 0.198 0.116
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant BMP6 and the recovery rates were calculated by comparing the measured value to the expected amount of BMP6 in samples.
Matrix Recovery range Average
serum(n=5) 80-92% 86%
EDTA plasma(n=5) 90-105% 97%
Heparin plasma(n=5) 88-102% 95%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of BMP6 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-92% 89-102% 87-98% 80-92%
EDTA plasma(n=5) 98-106% 86-99% 78-95% 89-97%
Heparin plasma(n=5) 85-94% 87-96% 92-101% 82-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
绥滨县| 斗六市| 平罗县| 留坝县| 杭锦旗| 梧州市| 铜鼓县| 武冈市| 雷波县| 五峰| 阜康市| 高邑县| 泾阳县| 西华县| 梁山县| 西昌市| 深州市| 来安县| 永登县| 平和县| 深水埗区| 常宁市| 贵溪市| 尉犁县| 白银市| 江源县| 敦化市| 泗洪县| 永川市| 涿鹿县| 米林县| 铁岭市| 葫芦岛市| 茶陵县| 双桥区| 中江县| 韶山市| 海伦市| 吴旗县| 德州市| 余庆县|