免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人腎上腺素能受體α1A(ADRa1A)酶聯(lián)免疫吸附檢測試劑盒
ELK1867
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human ADRa1A(Adrenergic Receptor Alpha 1A) ELISA Kit
Reactivity: Human
Alternative Names: ADR-A1A; ADRA1-A; ADRA1C; ADRA1L1; Alpha1AAR; Alpha 1a-Adrenoceptor
Assay Type: Sandwich
Sensitivity: 0.122 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Cardiovascular biology;
Uniprot ID: P35348
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ADRa1A. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ADRa1A. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ADRa1A, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ADRa1A in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.052 1.949
10.00 1.566 1.463
5.00 1.243 1.140
2.50 0.848 0.745
1.25 0.507 0.404
0.63 0.327 0.224
0.32 0.217 0.114
0.00 0.103 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ADRa1A and the recovery rates were calculated by comparing the measured value to the expected amount of ADRa1A in samples.
Matrix Recovery range Average
serum(n=5) 84-93% 87%
EDTA plasma(n=5) 95-108% 101%
Heparin plasma(n=5) 82-97% 89%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ADRa1A and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-102% 81-96% 87-105% 83-92%
EDTA plasma(n=5) 88-99% 81-93% 89-97% 85-94%
Heparin plasma(n=5) 87-96% 82-95% 93-102% 87-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
民权县| 咸宁市| 广安市| 黄冈市| 霍城县| 高青县| 海门市| 昔阳县| 福建省| 新河县| 伊金霍洛旗| 灌阳县| 德昌县| 海城市| 青阳县| 东宁县| 子长县| 若羌县| 大理市| 环江| 南安市| 澳门| 响水县| 中牟县| 旬阳县| 安图县| 墨竹工卡县| 萨嘎县| 八宿县| 泊头市| 牙克石市| 陵水| 印江| 紫阳县| 敦煌市| 黄龙县| 如皋市| 庆阳市| 吉水县| 舒兰市| 家居|