免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人微管關(guān)聯(lián)蛋白4(MAP4)酶聯(lián)免疫吸附檢測試劑盒
ELK1880
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human MAP4(Microtubule Associated Protein 4) ELISA Kit
Reactivity: Human
Alternative Names: DKFZp779A1753 ;MAP-4
Assay Type: Sandwich
Sensitivity: 0.098 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Neuro science;
Uniprot ID: P27816
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MAP4. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MAP4. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MAP4, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MAP4 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.096 2.023
10.00 1.502 1.429
5.00 1.174 1.101
2.50 0.907 0.834
1.25 0.518 0.445
0.63 0.312 0.239
0.32 0.168 0.095
0.00 0.073 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MAP4 and the recovery rates were calculated by comparing the measured value to the expected amount of MAP4 in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 80-95% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MAP4 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 96-104% 90-102% 87-98% 95-103%
EDTA plasma(n=5) 87-103% 97-105% 79-90% 87-96%
Heparin plasma(n=5) 93-99% 87-101% 85-95% 85-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
安溪县| 会东县| 阆中市| 佳木斯市| 巨野县| 常德市| 安塞县| 旬阳县| 屯门区| 卢湾区| 新河县| 顺义区| 顺昌县| 任丘市| 台州市| 板桥市| 龙州县| 舒城县| 宜良县| 桂阳县| 内乡县| 镇巴县| 正镶白旗| 聂拉木县| 雷州市| 武陟县| 桐庐县| 上栗县| 吉木乃县| 巩义市| 杂多县| 湘阴县| 乌拉特前旗| 阳新县| 三都| 武隆县| 安乡县| 京山县| 富锦市| 鄂伦春自治旗| 汪清县|