免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人丙酮酸激酶(PK)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1922
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human PK(Pyruvate Kinase, Liver And RBC) ELISA Kit
Reactivity: Human
Alternative Names: PKLR; PyK; PK1; PKL; Pyruvate Kinase Isozymes R/L; Glutamic--pyruvic transaminase 1; R-type/L-type pyruvate kinase; Red cell/liver pyruvate kinase
Assay Type: Sandwich
Sensitivity: 17 pg/mL
Standard: 2500 pg/mL
Detection Range: 39.07-2500 pg/mL
Sample Type: Tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;
Uniprot ID: P30613
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PK. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human PK. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human PK, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PK in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2500.00 1.990 1.897
1250.00 1.506 1.413
625.00 1.144 1.051
312.50 0.975 0.882
156.25 0.593 0.500
78.13 0.326 0.233
39.07 0.192 0.099
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PK and the recovery rates were calculated by comparing the measured value to the expected amount of PK in samples.
Matrix Recovery range Average
serum(n=5) 80-90% 85%
EDTA plasma(n=5) 84-106% 100%
Heparin plasma(n=5) 87-93% 90%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PK and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-94% 85-95% 89-99% 85-95%
EDTA plasma(n=5) 85-94% 87-96% 92-101% 82-98%
Heparin plasma(n=5) 87-96% 85-98% 89-102% 85-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
昌吉市| 永平县| 成武县| 黄石市| 西宁市| 临湘市| 郯城县| 黔西县| 华容县| 富顺县| 罗山县| 东山县| 蒲城县| 昆山市| 呼伦贝尔市| 台东市| 木里| 班玛县| 洮南市| 辽中县| 于都县| 梁河县| 桐柏县| 遂平县| 罗城| 紫金县| 南丰县| 南丰县| 泾阳县| 四子王旗| 宜春市| 贵港市| 西青区| 江川县| 兰溪市| 吉木乃县| 汉沽区| 安顺市| 离岛区| 新巴尔虎左旗| 黄龙县|