免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠Ⅰ型膠原交聯(lián)羧基端肽(CTXI)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK2223
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Mouse CTXI(Cross Linked C-Telopeptide Of Type I Collagen) ELISA Kit
Reactivity: Mouse
Alternative Names: CTX-I; CTX1;
Assay Type: Competitive Inhibition
Sensitivity: 49.1 pg/mL
Standard: 10000 pg/mL
Detection Range: 156.25-10000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Metabolic pathway;Bone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Mouse CTXI protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CTXI. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CTXI in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
10000.00 0.197
5000.00 0.332
2500.00 0.575
1250.00 0.823
625.00 1.157
312.50 1.592
156.25 1.715
0.00 2.226

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CTXI and the recovery rates were calculated by comparing the measured value to the expected amount of CTXI in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 81-95% 88%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CTXI and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-96% 85-98% 95-103% 88-95%
EDTA plasma(n=5) 86-93% 88-92% 86-97% 90-101%
Heparin plasma(n=5) 91-102% 89-97% 86-102% 94-106%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
吉安市| 南郑县| 甘孜| 南投市| 乌鲁木齐市| 屏边| 宁蒗| 灵宝市| 江北区| 新化县| 陵水| 那曲县| 磐石市| 黄冈市| 樟树市| 青神县| 旌德县| 靖远县| 时尚| 黔西| 乐东| 克拉玛依市| 山西省| 镇坪县| 濮阳县| 沙田区| 阳泉市| 武胜县| 东山县| 泸西县| 福安市| 吉林市| 阜阳市| 遵义市| 屏边| 四平市| 盐城市| 启东市| 确山县| 万山特区| 垦利县|