免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人骨成型蛋白7(BMP7)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK2635
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human BMP7(Bone Morphogenetic Protein 7) ELISA Kit
Reactivity: Human
Alternative Names: OP1; Osteogenic Protein-1; Eptotermin alfa
Assay Type: Sandwich
Sensitivity: 27.4 pg/mL
Standard: 4000 pg/mL
Detection Range: 62.5-4000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Developmental science;Bone metabolism;
Uniprot ID: P18075
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human BMP7. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human BMP7. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human BMP7, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human BMP7 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
4000.00 2.266 2.174
2000.00 1.563 1.471
1000.00 1.174 1.082
500.00 0.963 0.871
250.00 0.572 0.480
125.00 0.388 0.296
62.50 0.185 0.093
0.00 0.092 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant BMP7 and the recovery rates were calculated by comparing the measured value to the expected amount of BMP7 in samples.
Matrix Recovery range Average
serum(n=5) 95-107% 101%
EDTA plasma(n=5) 96-104% 100%
Heparin plasma(n=5) 98-104% 102%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of BMP7 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 90-99% 87-103% 82-97%
EDTA plasma(n=5) 85-94% 90-99% 82-101% 91-102%
Heparin plasma(n=5) 95-106% 89-102% 87-98% 85-92%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
绍兴市| 崇明县| 江孜县| 磴口县| 环江| 利辛县| 亚东县| 天全县| 万州区| 金堂县| 尚志市| 黎川县| 孟津县| 广汉市| 宝坻区| 建湖县| 昌图县| 南郑县| 江西省| 日土县| 新昌县| 马鞍山市| 盐源县| 芦溪县| 津市市| 达日县| 连平县| 东光县| 盈江县| 蓬莱市| 留坝县| 彭山县| 吴旗县| 翁牛特旗| 教育| 北流市| 丰顺县| 大兴区| 萨嘎县| 青龙| 大足县|