免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠鈣網(wǎng)蛋白(CRT)酶聯(lián)免疫吸附檢測試劑盒
ELK3182
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Mouse CRT(Calreticulin) ELISA Kit
Reactivity: Mouse
Alternative Names: CALR; RO; SSA; CC1qR; ERp60; HACBP; grp60; CRTC; CRP55; Calregulin; Sicca Syndrome Antigen A; Autoantigen Ro; Endoplasmic reticulum resident protein 60
Assay Type: Sandwich
Sensitivity: 0.067 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Metabolic pathway;Bone metabolism;
Uniprot ID: P14211
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CRT. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CRT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CRT, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CRT in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.166 2.089
5.00 1.621 1.544
2.50 0.997 0.920
1.25 0.777 0.700
0.63 0.532 0.455
0.32 0.351 0.274
0.16 0.206 0.129
0.00 0.077 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CRT and the recovery rates were calculated by comparing the measured value to the expected amount of CRT in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 89-103% 96%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CRT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 79-96% 92-101% 83-90%
EDTA plasma(n=5) 95-102% 93-101% 97-105% 95-103%
Heparin plasma(n=5) 88-97% 86-92% 81-93% 89-105%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
常宁市| 威信县| 景东| 海门市| 镇平县| 万安县| 府谷县| 宁安市| 常山县| 拜泉县| 楚雄市| 崇信县| 绵竹市| 图木舒克市| 阿拉善盟| 东港市| 雷山县| 顺平县| 高邮市| 武平县| 鄂托克前旗| 平陆县| 桦南县| 陇川县| 盐源县| 耿马| 通化市| 东至县| 南召县| SHOW| 竹山县| 石城县| 抚松县| 镇赉县| 宝坻区| 云和县| 柳林县| 阜平县| 湟中县| 通榆县| 五华县|