免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產品中心

人癌胚抗原相關細胞粘附分子8(CEACAM8)酶聯免疫吸附檢測試劑盒
ELK3879
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Human CEACAM8(Carcinoembryonic Antigen Related Cell Adhesion Molecule 8) ELISA Kit
Reactivity: Human
Alternative Names: CD67; CD66-B; CD66b; CGM6; NCA95; Carcinoembryonic antigen CGM6; Non-specific cross-reacting antigen NCA-95
Assay Type: Sandwich
Sensitivity: 5.8 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: CD & Adhesion molecule;
Uniprot ID: P31997
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CEACAM8. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CEACAM8. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CEACAM8, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CEACAM8 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 1.958 1.872
500.00 1.638 1.552
250.00 1.277 1.191
125.00 0.937 0.851
62.50 0.538 0.452
31.25 0.381 0.295
15.63 0.168 0.082
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CEACAM8 and the recovery rates were calculated by comparing the measured value to the expected amount of CEACAM8 in samples.
Matrix Recovery range Average
serum(n=5) 91-105% 98%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 80-94% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CEACAM8 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-103% 81-91% 85-101% 81-90%
EDTA plasma(n=5) 83-92% 92-96% 86-98% 95-101%
Heparin plasma(n=5) 89-101% 79-92% 82-93% 83-97%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
星子县| 定远县| 武川县| 监利县| 兴宁市| 乌拉特后旗| 庄浪县| 台州市| 余姚市| 进贤县| 大竹县| 靖安县| 西藏| 无棣县| 溆浦县| 历史| 台江县| 德惠市| 七台河市| 陕西省| 东兰县| 松江区| 潮州市| 大关县| 南木林县| 宣城市| 邵东县| 皋兰县| 安义县| 台中市| 珲春市| 成安县| 清涧县| 任丘市| 宣化县| 阳东县| 融水| 西和县| 蒙城县| 台北县| 修文县|