免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人線粒體融合素1(MFN1)酶聯(lián)免疫吸附檢測試劑盒
ELK5213
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Human MFN1(Mitofusin 1) ELISA Kit
Reactivity: Human
Alternative Names: Hfzo1; Hfzo2; Transmembrane GTPase MFN1; Fzo homolog
Assay Type: Sandwich
Sensitivity: 0.059 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Neuro science;
Uniprot ID: Q8IWA4
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MFN1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MFN1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MFN1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MFN1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.153 2.045
5.00 1.583 1.475
2.50 1.087 0.979
1.25 0.775 0.667
0.63 0.553 0.445
0.32 0.336 0.228
0.16 0.214 0.106
0.00 0.108 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MFN1 and the recovery rates were calculated by comparing the measured value to the expected amount of MFN1 in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MFN1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-95% 96-105% 85-96% 90-99%
EDTA plasma(n=5) 88-97% 95-106% 83-98% 93-105%
Heparin plasma(n=5) 82-94% 85-96% 78-90% 91-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
绿春县| 高陵县| 综艺| 区。| 祁东县| 辽中县| 精河县| 手机| 佛山市| 吴江市| 永登县| 昌黎县| 萍乡市| 汾西县| 中山市| 百色市| 驻马店市| 金塔县| 平南县| 嘉鱼县| 西丰县| 柳州市| 广州市| 临清市| 且末县| 驻马店市| 原平市| 苏尼特左旗| 岱山县| 闻喜县| 五原县| 开江县| 九寨沟县| 腾冲县| 双辽市| 边坝县| 许昌县| 建瓯市| 基隆市| 五家渠市| 和静县|