免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠硬脂酰輔酶A去飽和酶(SCD)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK6972
規(guī)格: 價(jià)格:
48T ¥2240.00
96T ¥3200.00

Overview 文獻(xiàn)

Product name: Mouse SCD(Stearoyl Coenzyme A Desaturase) ELISA Kit
Reactivity: Mouse
Alternative Names: FADS5; SCDOS; Fatty Acid desaturase 5; Delta-9-Desaturase; Stearoyl-CoA Desaturase Opposite Strand
Assay Type: Sandwich
Sensitivity: 0.056 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Enzyme & Kinase;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse SCD. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse SCD. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse SCD, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse SCD in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.058 1.965
5.00 1.616 1.523
2.50 1.223 1.130
1.25 0.855 0.762
0.63 0.527 0.434
0.32 0.366 0.273
0.16 0.225 0.132
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SCD and the recovery rates were calculated by comparing the measured value to the expected amount of SCD in samples.
Matrix Recovery range Average
serum(n=5) 80-97% 88%
EDTA plasma(n=5) 95-108% 101%
Heparin plasma(n=5) 83-97% 90%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SCD and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-91% 95-104% 93-102% 79-94%
EDTA plasma(n=5) 87-96% 82-95% 93-102% 87-96%
Heparin plasma(n=5) 93-106% 87-99% 85-93% 79-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
台南县| 绥棱县| 山东省| 夏河县| 黄石市| 唐海县| 河北省| 林口县| 佛山市| 神木县| 龙州县| 宜黄县| 望谟县| 榆林市| 萨嘎县| 韶山市| 涞水县| 德化县| 图木舒克市| 兰溪市| 布尔津县| 兰考县| 汾阳市| 蚌埠市| 湖南省| 武穴市| 安阳市| 宿州市| 霍林郭勒市| 厦门市| 凤山市| 达日县| 晋江市| 深圳市| 昆明市| 金阳县| 宜城市| 贺兰县| 新丰县| 永州市| 涞源县|