免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

環(huán)磷酸腺苷(cAMP)酶聯(lián)免疫吸附檢測試劑盒
ELK8116
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: cAMP(Cyclic Adenosine Monophosphate) ELISA Kit
Reactivity: General
Alternative Names: c-AMP; 3'-5'-Cyclic Adenosine Monophosphate; Adenosine Cyclophosphate
Assay Type: Competitive Inhibition
Sensitivity: 92.5 pg/mL
Standard: 20000 pg/mL
Detection Range: 312.5-20000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Signal transduction;Metabolic pathway;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with cAMP protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to cAMP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of cAMP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
20000.00 0.237
10000.00 0.411
5000.00 0.715
2500.00 0.913
1250.00 1.225
625.00 1.579
312.50 1.813
0.00 2.211

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant cAMP and the recovery rates were calculated by comparing the measured value to the expected amount of cAMP in samples.
Matrix Recovery range Average
serum(n=5) 93-105% 99%
EDTA plasma(n=5) 84-93% 89%
Heparin plasma(n=5) 81-103% 94%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of cAMP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-93% 91-105% 85-103% 89-97%
EDTA plasma(n=5) 95-104% 93-105% 82-101% 91-103%
Heparin plasma(n=5) 83-95% 96-105% 85-96% 90-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
桑植县| 轮台县| 西丰县| 师宗县| 高碑店市| 左云县| 上林县| 德州市| 翁牛特旗| 昌宁县| 依安县| 苍溪县| 青冈县| 宜君县| 赤壁市| 昌图县| 安平县| 炎陵县| 镇赉县| 宜宾县| 湟源县| 常山县| 鹤壁市| 调兵山市| 丰宁| 卢湾区| 阿拉善左旗| 阿拉善左旗| 怀集县| 台北县| 汝南县| 乌鲁木齐市| 砀山县| 莱州市| 金湖县| 大宁县| 榕江县| 濉溪县| 建瓯市| 灵宝市| 郸城县|