免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人殺菌肽LL-37(LL-37)酶聯(lián)免疫吸附檢測試劑盒
ELK8189
規(guī)格: 價格:
48T ¥2240.00
96T ¥3200.00

Overview 文獻

Product name: Human LL-37(Antibacterial Protein LL-37) ELISA Kit
Reactivity: Human
Alternative Names: CAP18; FALL39; HSD26; LL37; 18 kDa Cationic Antimicrobial Protein; Antibacterial protein FALL-39; FALL-39 peptide antibiotic; CAMP; Cathelicidin Antimicrobial Peptide
Assay Type: Sandwich
Sensitivity: 0.27 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human LL-37. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human LL-37. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human LL-37, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human LL-37 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
50.00 2.054 1.971
25.00 1.587 1.504
12.50 1.027 0.944
6.25 0.866 0.783
3.13 0.509 0.426
1.57 0.335 0.252
0.79 0.228 0.145
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant LL-37 and the recovery rates were calculated by comparing the measured value to the expected amount of LL-37 in samples.
Matrix Recovery range Average
serum(n=5) 82-94% 88%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 82-94% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LL-37 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 83-94% 85-98% 85-97%
EDTA plasma(n=5) 98-105% 92-101% 85-105% 87-98%
Heparin plasma(n=5) 85-92% 79-96% 89-100% 85-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
彭阳县| 安阳市| 深州市| 太白县| 荥阳市| 牟定县| 双柏县| 安丘市| 巴南区| 迭部县| 根河市| 丹寨县| 新源县| 静海县| 时尚| 康定县| 蕲春县| 德清县| 区。| 东宁县| 古蔺县| 沙雅县| 镇康县| 清涧县| 东宁县| 清镇市| 望城县| 讷河市| 海城市| 慈溪市| 绥阳县| 安远县| 确山县| 兖州市| 无棣县| 黑河市| 巴楚县| 茶陵县| 西昌市| 乳源| 漾濞|