免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠γ-氨基丁酸(gABA)酶聯(lián)免疫吸附檢測試劑盒
ELK9167
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Rat gABA(Gamma-Aminobutyric Acid) ELISA Kit
Reactivity: Rat
Alternative Names: 4-Aminobutyric Acid
Assay Type: Competitive Inhibition
Sensitivity: 9.32 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Signal transduction;Cardiovascular biology;Neuro science;Bone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat gABA protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat gABA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat gABA in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2000.00 0.198
1000.00 0.376
500.00 0.589
250.00 0.812
125.00 1.253
62.50 1.537
31.25 1.775
0.00 2.226

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant gABA and the recovery rates were calculated by comparing the measured value to the expected amount of gABA in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 81-95% 88%
Heparin plasma(n=5) 80-95% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of gABA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-93% 87-96% 86-98% 92-101%
EDTA plasma(n=5) 95-104% 87-96% 88-101% 82-95%
Heparin plasma(n=5) 95-104% 89-100% 91-102% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
乌苏市| 资兴市| 肃宁县| 湘潭县| 娄底市| 桐庐县| 五莲县| 清丰县| 宜章县| 漳平市| 咸宁市| 望江县| 固始县| 陆川县| 江津市| 清苑县| 资兴市| 杂多县| 元朗区| 台南市| 德庆县| 云和县| 商城县| 平原县| 新宁县| 红桥区| 年辖:市辖区| 郴州市| 博罗县| 东兰县| 湛江市| 宁陕县| 内丘县| 于田县| 锦州市| 共和县| 克拉玛依市| 大田县| 阿巴嘎旗| 习水县| 开化县|