免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人甘丙肽樣肽(GALP)酶聯(lián)免疫吸附檢測試劑盒
ELK9340
規(guī)格: 價格:
48T ¥2240.00
96T ¥3200.00

Overview 文獻(xiàn)

Product name: Human GALP(Galanin-like peptide) ELISA Kit
Reactivity: Human
Alternative Names: Galanin like peptide; Galanin like peptide precursor protein; Alarin splice variant; Alarin; GALP precursor protein
Assay Type: Sandwich
Sensitivity: 29 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Signal transduction; Neuroscience; Cardiovascular; Developmental Biology
Uniprot ID: Q9UBC7
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GALP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GALP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human GALP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GALP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 1.972 1.885
2500.00 1.708 1.621
1250.00 1.185 1.098
625.00 0.852 0.765
312.50 0.577 0.490
156.25 0.357 0.270
78.13 0.194 0.107
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GALP and the recovery rates were calculated by comparing the measured value to the expected amount of GALP in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 87-101% 94%
Heparin plasma(n=5) 83-97% 90%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GALP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 81-94% 83-96% 85-95% 82-91%
EDTA plasma(n=5) 86-93% 81-94% 85-96% 87-101%
Heparin plasma(n=5) 85-102% 79-92% 87-103% 89-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
东辽县| 广汉市| 溧阳市| 淳安县| 东方市| 乐业县| 康平县| 陕西省| 虞城县| 策勒县| 大竹县| 紫金县| 容城县| 寿阳县| 饶河县| 利辛县| 抚宁县| 鹿邑县| 凤庆县| 东城区| 泊头市| 宣恩县| 吴桥县| 武乡县| 新昌县| 鸡西市| 武威市| 通渭县| 明光市| 通化市| 应城市| 兴安县| 普兰县| 黔西县| 金乡县| 海城市| 辛集市| 达拉特旗| 广安市| 安康市| 朝阳县|