免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠可溶性CD40配體(sCD40L)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK9485
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Rat sCD40L(Soluble Cluster Of Differentiation 40 Ligand) ELISA Kit
Reactivity: Rat
Alternative Names: CD154; TRAP; HIGM1; IGM; IMD3; TBAM; T-BAM; TNFSF5; Gp39; TNF Superfamily Member 5; Hyper-IgM Syndrome; TNF-Related Activation Protein; T-Cell B-Cell Activating Molecule
Assay Type: Sandwich
Sensitivity: 6.4 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;CD & Adhesion molecule;Apoptosis;Tumor immunity;Infection immunity;Immune molecule;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat sCD40L. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat sCD40L. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat sCD40L, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat sCD40L in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.132 2.050
500.00 1.708 1.626
250.00 1.282 1.200
125.00 0.813 0.731
62.50 0.555 0.473
31.25 0.377 0.295
15.63 0.213 0.131
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant sCD40L and the recovery rates were calculated by comparing the measured value to the expected amount of sCD40L in samples.
Matrix Recovery range Average
serum(n=5) 83-95% 89%
EDTA plasma(n=5) 87-95% 91%
Heparin plasma(n=5) 78-92% 85%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of sCD40L and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 84-98% 91-97% 81-93% 78-91%
EDTA plasma(n=5) 87-98% 83-96% 78-98% 90-99%
Heparin plasma(n=5) 83-96% 86-97% 90-98% 80-93%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
深圳市| 万源市| 邓州市| 彩票| 德兴市| 磐石市| 安阳县| 安徽省| 格尔木市| 手游| 友谊县| 泗洪县| 三门峡市| 南靖县| 高阳县| 江油市| 治县。| 恩平市| 常德市| 临安市| 怀来县| 枣阳市| 调兵山市| 广南县| 丰都县| 静乐县| 凤山县| 东乌珠穆沁旗| 武义县| 耿马| 天气| 上杭县| 新邵县| 仲巴县| 蒲城县| 宜兰县| 庄浪县| 灵宝市| 韶关市| 邹城市| 普兰店市|