免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠核連蛋白2(NUCB2)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK9838
規(guī)格: 價(jià)格:
48T ¥2240.00
96T ¥3200.00

Overview 文獻(xiàn)

Product name: Mouse NUCB2(Nucleobindin 2) ELISA Kit
Reactivity: Mouse
Alternative Names: NUCB2; NEFA; Nucleobindin 2; DNA-binding protein NEFA; Gastric cancer antigen Zg4; Prepronesfatin
Assay Type: Sandwich
Sensitivity: 0.102 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Serum, plasma and other biological fluids.
Assay Length: 3.5h
Research Area: Signal transduction;
Uniprot ID: P81117
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse NUCB2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse NUCB2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse NUCB2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse NUCB2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.201 2.114
10.00 1.612 1.525
5.00 1.273 1.186
2.50 0.871 0.784
1.25 0.567 0.480
0.63 0.323 0.236
0.32 0.258 0.171
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NUCB2 and the recovery rates were calculated by comparing the measured value to the expected amount of NUCB2 in samples.
Matrix Recovery range Average
serum(n=5) 85-99% 92%
EDTA plasma(n=5) 92-106% 99%
Heparin plasma(n=5) 81-97% 89%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NUCB2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-92% 86-97% 90-101% 92-102%
EDTA plasma(n=5) 85-97% 95-107% 85-94% 82-96%
Heparin plasma(n=5) 83-89% 88-104% 97-103% 89-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
兴文县| 白朗县| 扎兰屯市| 明溪县| 邵阳县| 临沂市| 奎屯市| 阜新市| 济源市| 长沙县| 富民县| 金昌市| 涿州市| 公安县| 图木舒克市| 嘉黎县| 巴中市| 祁连县| 洪洞县| 化隆| 繁昌县| 邻水| 陆丰市| 镇雄县| 兰溪市| 阳西县| 云安县| 安福县| 夏邑县| 百色市| 克什克腾旗| 北票市| 中江县| 涟水县| 泰和县| 西昌市| 韶关市| 旅游| 榆树市| 闽侯县| 安吉县|